Page 2

9GP-4100 Series Model Name IndicationModel nameG P 41 0 * * 1 DGP-4100 Series Model NamesGlobal CodeA global code is assigned to every Pro-face produc

Page 3 - Essential Safety Precautions

10Package ContentsThe following items are included in the GP unit’s package. Before using the GP, please check that all items listed here are present.

Page 4

11UL/c-UL Approval• UL listed products• c-UL listed products• Product ListUL/c-UL File No.: E220851, E210412<Cautions> Be aware of the following

Page 5

12(4) Control Drawing of USB (Type A) Interface (USB1)The information below concerns the use of the USB interface used in Class I, Division 2, Groups

Page 6

13CE MarkingThe following units are CE marked products complying with the EMC Directive.They comply with EN61000-6-2, EN61000-6-4. and EN61131-2About

Page 7

14ContentsPreface... 1Essential Saf

Page 8 - LCD Panel Usage Precautions

15Chapter 4 Installation and Wiring4.1 Installation...

Page 10 - Global Code

1-11 Accessories/System Design1. Accessories2. System design

Page 11 - Package Contents

GP-4100 Series Hardware Manual1-21.1 AccessoriesAll accessories listed here are produced by Pro-face.1.1.1Serial Interface Item1.1.2 USB (Type A) Inte

Page 12 - UL/c-UL Approval

1PrefaceThank you for purchasing Pro-face’s GP-4100 Series Programmable Operator Interface (Hereafter referred to as the “GP unit”).Before operating y

Page 13

Chapter 1 Accessories/System Design1-31.1.5 Maintenance ItemsProduct Name Model No. Description3.4-inch Installation FastenerZC9AF31Used to install th

Page 14 - About Revision

GP-4100 Series Hardware Manual1-41.2System designThe following diagram illustrates the standard range of items that can be connected to GP-4100 Series

Page 15 - Contents

Chapter 1 Accessories/System Design1-5Ethernet communication• Only GP-4104 supports Ethernet communication.GP4104Ethernet Interface(10BASE-T/100BASE-

Page 16 - After-sales Service

GP-4100 Series Hardware Manual1-6USB (Type A)/ USB (mini-B) Interface• If connecting a bar code reader to the GP, be sure to supply power from an ext

Page 17

Chapter 1 Accessories/System Design1-71.2.2 Edit Mode PeripheralsGP-4100 SeriesUSB (Type A) Interface(USB1)Ethernet Interface(10BASE-T/100BASE-TX)Only

Page 18 - 1 Accessories/

GP-4100 Series Hardware Manual1-8

Page 19 - 1.1.4 Option Items

2-12 Part Names and Functions1. GP-4100 SeriesThis chapter describes the GP’s part name and functions of each part.

Page 20 - 1.1.5 Maintenance Items

GP-4100 Series Hardware Manual2-22.1 GP-4100 SeriesA: Power ConnectorB: Serial Interface (COM1)RS-232C and RS-422/485 Types: 9-pin, 2-piece terminal

Page 21 - System design

Chapter 2 Part Names and Functions2-3F: Ethernet InterfaceThe Ethernet transmission interface (10BASE-T/100BASE-TX). An RJ-45 type modular jack conne

Page 22 - Ethernet communication

GP-4100 Series Hardware Manual2-4

Page 23

2Essential Safety PrecautionsAll safety-related procedures stated in this document must be followed to operate the GP correctly and safely. Be sure to

Page 24 - 1.2.2 Edit Mode Peripherals

3-13 Specifications1. GP-4100 SeriesThis chapter describes the general, functional and interface specifications of the GP as well as its dimensions.

Page 25

GP-4100 Series Hardware Manual3-23.1 GP-4100 Series3.1.1 General SpecificationsElectrical SpecificationsGP4104/4105 GP4106 GP4107Power SupplyInput Vo

Page 26 - 2 Part Names and

Chapter 3 Specifications3-3Environmental SpecificationsPhysicalSurrounding Air Temperature 0 to 50°C*1*1 When using in an environment where the tempe

Page 27 - LINK LED

GP-4100 Series Hardware Manual3-4Structural Specifications InstallationGroundingFunctional grounding:Grounding resistance of 100, 2mm2 (14 AWG)

Page 28

Chapter 3 Specifications3-53.1.2 Performance SpecificationsPerformance SpecificationsGP4104 GP4105 GP4106 GP4107Application Memory*1*1 Capacity avail

Page 29

GP-4100 Series Hardware Manual3-6Display SpecificationsGP4104G/4105G/4106G/4107GGP4104W/4105W/4106W/4107WDisplay Type STN Monochrome LCDDisplay Size

Page 30 - 3 Specifications

Chapter 3 Specifications3-7Touch Panel Specifications Multiple touch operation on GP-4100 Series may cause unexpected input around the center of tou

Page 31 - 3.1 GP-4100 Series

GP-4100 Series Hardware Manual3-83.1.3 Serial Interface RS-232C and RS-422/485 Types (GP4105/GP4106)Included COM I/F connector(9-pin, 2-piece termina

Page 32 - Environmental Specifications

Chapter 3 Specifications3-9Communications Cable SpecificationsWiring the COM Interface Connector(1) Remove the COM I/F connector from the GP.(2) Use

Page 33

GP-4100 Series Hardware Manual3-10 RS-485 (isolation) type (GP4107)<GP unit side>D-Sub 9-pin socket type connectorInterfit Bracket #4-40 inch s

Page 34 - Performance Specifications

3WARNINGHAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH• NEVER touch a live power terminal. Doing so could cause an electrical shock or a machine ma

Page 35 - Display Specifications

Chapter 3 Specifications3-113.1.4 DimensionsExternal Dimensions (1)Unit: mm[in.]• The dimensions for models with the following type of power connecto

Page 36 - Touch Panel Specifications

GP-4100 Series Hardware Manual3-12External Dimensions (2)Unit: mm[in.]• The dimensions for models with the following type of power connector are show

Page 37 - 3.1.3 Serial Interface

Chapter 3 Specifications3-13Installation Fasteners Attached DimensionsThe figure shows the RS-422/485 type (GP4106), but all dimensions are common wi

Page 38

GP-4100 Series Hardware Manual3-14 Cable Attached DimensionsUnit: mm[in.]• For models with the following type of power connector, the dimensions for

Page 39

Chapter 3 Specifications3-15Unit: mm[in.]• For models with the following type of power connector, the dimensions for the RS-485 (isolation) type (GP41

Page 40 - External Dimensions (1)

GP-4100 Series Hardware Manual3-16 Unit: mm[in.]• The dimensions for models with the following type of power connector are shown next.• All the above

Page 41 - External Dimensions (2)

Chapter 3 Specifications3-17Panel Cut DimensionsUnit: mm[in.]Installation FastenersUnit: mm[in.]• Please read “4.1 Installation” before designing th

Page 42

GP-4100 Series Hardware Manual3-18

Page 43 -  Cable Attached Dimensions

4-14 Installation and Wiring1. Installation2. Wiring Precautions 3. USB Cable Clamp Attachment/Removal

Page 44

GP-4100 Series Hardware Manual4-24.1 InstallationThis section describes the procedures and precautions for installing the GP Series units.Check the I

Page 45

4WARNINGUNINTENDED EQUIPMENT OPERATION OR LOSS OF CONTROL• Do not make switches using the switches on the touch panels which may cause operator injury

Page 46 - Installation Fasteners

Chapter 4 Installation and Wiring4-3Installation Requirements• For easier maintenance, operation, and improved ventilation, be sure to install the GP

Page 47

GP-4100 Series Hardware Manual4-4• When installing the GP in a slanted panel, the panel face should not incline more than 30°.• When installing the GP

Page 48 - 4 Installation and

Chapter 4 Installation and Wiring4-5Installing the GP(1) Insert the GP into the panel cut, as shown.*1 GP units with Rev.1 or higher have projections

Page 49 - 4.1 Installation

GP-4100 Series Hardware Manual4-6• Tightening the screws with too much force can damage the GP unit’s plastic case.• In order to guarantee water repel

Page 50 - Installation Requirements

Chapter 4 Installation and Wiring4-74.2 Wiring PrecautionsThis section describes the procedures and precautions for wiring power cords.4.2.1 Connectin

Page 51

GP-4100 Series Hardware Manual4-8Power Cord SpecificationsPower Connector SpecificationsConnecting the Power Cord(1) Confirm that the GP unit’s Pow

Page 52 - Installing the GP

Chapter 4 Installation and Wiring4-9(4) Use a flat-blade screwdriver to tighten the appropriate terminal screws on the terminal connec-tor from step 3

Page 53

GP-4100 Series Hardware Manual4-10Power Cord SpecificationsPower Connector (Plug) SpecificationsWARNINGHAZARD OF ELECTRIC SHOCK• Prior to connecting

Page 54 - 4.2 Wiring Precautions

Chapter 4 Installation and Wiring4-11Connecting the Power Cord(1) Confirm that the power cord is unplugged from the power supply.(2) Check the rated

Page 55 - Connecting the Power Cord

GP-4100 Series Hardware Manual4-124.2.2 Connecting the Power SupplyThis section describes the precautions for supplying a power voltage.• If the suppl

Page 56

5WARNINGUNINTENDED EQUIPMENT OPERATION OR LOSS OF CONTROL• The cables connected to the GP should be secured by cable clamps to prevent weight or tensi

Page 57

Chapter 4 Installation and Wiring4-134.2.3 GroundingThis section describes the precautions for grounding the GP unit.• When supplying power to the GP

Page 58

GP-4100 Series Hardware Manual4-144.2.4 Wiring PrecautionsTo help prevent noise and interference problems, separate all control, communication and pow

Page 59 - Transformer

Chapter 4 Installation and Wiring4-154.3 USB Cable Clamp Attachment/RemovalThis clamp is used to prevent the USB cable connected to the USB Interface

Page 60 - 4.2.3 Grounding

GP-4100 Series Hardware Manual4-16Removal(1) Lift down the tab of the USB Holder and then remove the USB cover and the USB cable as shown.(2) Insert

Page 61 - 4.2.4 Wiring Precautions

Chapter 4 Installation and Wiring4-174.3.2 USB (mini-B) InterfaceAttachment(1) Insert the USB cable into the USB (mini-B) interface.(2) Hold the clam

Page 62 - Attachment

GP-4100 Series Hardware Manual4-18Removal(1) The clamp can be removed by squeezing the sides of the clamp and pulling, as shown in the Figure.2) Pull

Page 63 - Removal

5-15 Maintenance1. Cleaning the Display2. Periodic Check Points3. Replacing the Installation Gasket4. Replacing the BacklightThis chapter explains cau

Page 64 - 4.3.2 USB (mini-B) Interface

GP-4100 Series Hardware Manual5-25.1 Cleaning the DisplayWhen the surface or frame of the display become dirty, soak a soft cloth in water with a neut

Page 65

Chapter 5 Maintenance5-35.2 Periodic Check PointsTo keep your GP unit in its best condition, please inspect the following points periodically.GP Ope

Page 66 - 5 Maintenance

GP-4100 Series Hardware Manual5-45.3 Replacing the Installation GasketThe installation gasket provides protection against dust and moisture.Installat

Page 67 - 5.1 Cleaning the Display

6CAUTIONEYE IRRITANT• The unit's liquid crystal panel contains a powerful irritant. If, for any reason, the panel is damaged and this liquid ente

Page 68 - 5.2 Periodic Check Points

Chapter 5 Maintenance5-5• The gasket must be inserted correctly into the groove for the GP’s moisture resis-tance.• Since the gasket is flexible but

Page 69

GP-4100 Series Hardware Manual5-65.4 Replacing the Backlight• The backlight of the GP-4100 Series cannot be replaced by the user. When the backlight n

Page 70

After-sales ServiceFor details on after-sales service, refer to Pro-face website at http://www.pro-face.com/trans/en/manual/1001.html

Page 71 - 5.4 Replacing the Backlight

GP-4100 Series Hardware Manual

Page 72

7LCD Panel Usage Precautions• The LCD panel’s liquid contains an irritant. If the panel is damaged and any of this liquid contacts your skin, immedi-a

Page 73

8About the ManualsFor the detailed information on GP-4100 Series, refer to the following manuals.• Maintenance/Troubleshooting For the Offline Setting

Commentaires sur ces manuels

Pas de commentaire